Rated Capacity | 25t |
Full Scale Output | 2mV/V ± 0.25% |
Zero Balance | ± 0.02mV/V |
Non-linearity | < ± 0.030% |
Repeatability | < ± 0.017% |
Hysteresis Error | < ± 0.023% |
Creep in 30 minutes | < ± 0.023% |
Input Resistance | 700Ω ± 10Ω |
Output Resistance | 700Ω ± 5Ω |
Recommended Excitation | 10V (15V Maximum) |
Insulation Resistance | > 2GΩ (50V DC) |
Temperature Effect on Sensitivity | < ±0.0012% of Cn/k |
Temperature Effect on Zero Balance | < ± 0.0040% of Cn/k |
Compensated Temperature Range | –10°C to 50°C/14°F to 122°F |
Service Temperature Range | –30°C to 70°C/-20°F to 160°F |
Storage Temperature Range | -50°C to 85°C/-58°F to 185°F |
Safe Overload | 150% of full scale |
Breaking Overload | 300% of full scale |
Seal Type | Welded sealed |
IP Rating | IP67 |
Double Ended Shear Beams, Load Cells
102MH Double Ended Beam Load Cell
Description:
The 102MH is a heavy-duty medium-capacity double-ended beam load cell with IP67 water resistance. This model is particularly well-suited to onboard weighing and weighing-in-motion applications.
Features:
- Material: Alloy steel
- Rated Capacity: 25t
- Full Scale Output: 2mV/V ± 0.25%
- Safe Overload: 150%
- Breaking Overload: 300%
- IP Rating: IP67
- CE, RoHS and Ex certified
Note: You may need a software that can open/view STEP files.