Rated Capacities | 3kg, 6kg, 7kg, 10kg, 15kg, 20kg, 30kg, 35kg, 40kg, 45kg, 50kg, 60kg, 75kg, 100kg, 150kg |
Reference Max. Platform Size | 400mm x 400mm |
Full Scale Output | 2mV/V ± 10% |
Zero Balance | ±0.02mV/V |
Non-linearity | < ± 0.017% |
Repeatability | < ± 0.017% |
Hysteresis Error | < ± 0.017% |
Creep in 30 minutes | < ± 0.023% |
Input Resistance | 415Ω ± 15Ω |
Output Resistance | 350Ω ± 3Ω |
Recommended Excitation | 10V (15V Maximum) |
Insulation Resistance | > 2GΩ (50V DC) |
Temperature Effect on Sensitivity | < ±0.0012% of Cn/k |
Temperature Effect on Zero Balance | < ± 0.0040% of Cn/k |
Nominal Temperature Range | –10°C to 40°C/14°F to 104°F |
Service Temperature Range | –18°C to 65°C/0°F to 149°F |
Storage Temperature Range | -50°C to 85°C/-58°F to 185°F |
Safe Overload | 150% of full scale |
Breaking Overload | 300% of full scale |
Seal Type | Environmentally sealed |
IP Rating | IP66 |
Load Cells, Single Point
108BA Single Point Load Cell
Description:
The 108BA is a versatile and economic weighing solution for lower-capacity applications. It is compatible with a variety of models from other manufacturers (see: INTERCHANGEABLE tab), but has superior safe overload tolerance and selection of rated capacities. OIML and NTEP certified, with IP66 water resistance, this model is reliable and easy to install. This cost-effective load cell is popular in OEM applications, retail scales, other small packaging and process weighing systems, and platform scales.
Features:
- Material: Aluminum
- Rated Capacities: 3kg, 6kg, 7kg, 10kg, 15kg, 20kg, 30kg, 35kg, 40kg, 45kg, 50kg, 60kg, 75kg, 100kg, 150kg
- Full Scale Output: 2mV/V ± 10%
- Safe Overload: 150%
- Breaking Overload: 300%
- IP Rating: IP66
- 5 kg up to 50 kg: Certified up to OIML MAA C4, Y=15000
- 50 kg up to & including 150 kg: Certified up to OIML MAA C5, Y=12300
- CE, RoHS, NTEP, and Ex certified
Manufacturer | Model |
Mettler-Toledo | MT1022 |
Flintec | PC22* |
HBM | PW6C** |
HBM | PW6K |
Rice Lake | RL1521A |
Vishay Celtron | LPS ME 6-35kg |
Vishay Tedea-Huntleigh | 1022 |
* PC22 : 6-wire cable, the shielding wire connected to the sensor body, width of 20kg and 30kg is 30mm
** Full scale output of PW6C: 2.2±0.2% mV/V