Rated Capacities | 250lb |
Reference Max. Platform Size | 400mm x 450mm |
Full Scale Output | 1mV/V ± 10% |
Zero Balance | ± 0.02mV/V |
Non-linearity | < ± 0.020% |
Repeatability | < ± 0.020% |
Hysteresis Error | < ± 0.020% |
Creep in 30 minutes | < ± 0.030% |
Input Resistance | 385Ω ± 15Ω |
Output Resistance | 350Ω ± 3Ω |
Recommended Excitation | 10V (15V Maximum) |
Insulation Resistance | > 2GΩ (50V DC) |
Temperature Effect on Sensitivity | < ±0.0012% of Cn/k |
Temperature Effect on Zero Balance | < ± 0.0040% of Cn/k |
Nominal Temperature Range | –10°C to 40°C/14°F to 104°F |
Service Temperature Range | –18°C to 65°C/0°F to 149°F |
Storage Temperature Range | -50°C to 85°C/-58°F to 185°F |
Safe Overload | 150% of full scale |
Breaking Overload | 300% of full scale |
Seal Type | Environmentally sealed |
IP Rating | IP66 |
Load Cells, Single Point
108QSFL Single Point Load Cell
Description:
Rugged stainless steel corrosion and water-resistant single point with a simple and cost-effective design that does not compromise on performance. Interchangeable with Rice Lake RLFLS and Avery Weigh-Tronix FLS.
Features:
- Material: Stainless steel
- Rated Capacities: 250lb
- Full Scale Output: 1mV/V ± 10%
- Safe Overload: 150%
- Breaking Overload: 300%
- IP Rating: IP66
- CE and RoHS certified
Note: You may need a software that can open/view STEP files.
Manufacturer | Model |
Avery Weigh-Tronix | FLS |
Rice Lake | RLFLS |