Rated Capacities | 6kg, 12kg, 20kg, 30kg, 50kg, 60kg |
Reference Max. Platform Size | 350mm x 350mm |
Full Scale Output | 2mV/V ± 1% |
Zero Balance | ± 0.02mV/V |
Non-linearity | < ± 0.03% |
Repeatability | < ± 0.02% |
Hysteresis Error | < ± 0.03% |
Creep in 30 minutes | < ± 0.03% |
Input Resistance | 385Ω ± 15Ω |
Output Resistance | 350Ω ± 3Ω |
Recommended Excitation | 10V (15V Maximum) |
Insulation Resistance | > 2GΩ (50V DC) |
Temperature Effect on Sensitivity | < ±0.0012% of Cn/k |
Temperature Effect on Zero Balance | < ± 0.0040% of Cn/k |
Compensated Temperature Range | –10°C to 50°C/14°F to 122°F |
Service Temperature Range | –30°C to 70°C/-20°F to 160°F |
Storage Temperature Range | -50°C to 85°C/-58°F to 185°F |
Safe Overload | 150% of full scale |
Breaking Overload | 300% of full scale |
Seal Type | Welded seal |
IP Rating | IP68 |
Single Point
651HS Single Point Load Cell
Description:
OIML certified C9 from 10kg-100kg, this single point load cell is the highest accuracy legal-for-trade load cell available in the world. With IP68 stainless steel construction, 14°F to 122°F temperature compensation, and 150% safe overload, the 651HS is the ultimate weighing solution suited to an immense variety of applications.
Features:
- Material: Stainless steel
- Rated Capacities: 6kg, 12kg, 20kg, 30kg, 50kg, 60kg
- Full Scale Output: 2mV/V ± 1%
- Safe Overload: 150%
- Breaking Overload: 300%
- IP Rating: IP68/69K
- OIML MAA C9, Y=18 000 certified from 10kg-100kg
- OIML MAA C4, Y=26 000 certified from 101kg-500kg
Note: You may need a software that can open/view STEP files.
Manufacturer | Model |
Vishay Revere Transducers | HPSM |